enviroDPMS (Round)

RH+T+DP CLEAN ROOM MONITOR
enviroDPMS-LED-Round

enviroDPMS (Round)

RH+T+DP CLEAN ROOM MONITOR

Assists in GMP and Data Integrity in multiple pharma clean rooms

  • Blue-Right-Arrow Micro-controller based

  • Blue-Right-Arrow RH, Temperature & DP measurement

  • Blue-Right-Arrow Seven Segment 4 digit display

  • Blue-Right-Arrow Software Programmable channel ranges, unit & input types

  • Blue-Right-Arrow User programmable for 1,2 or 3 channel measurement

  • Blue-Right-Arrow Real time clock with battery back-up with internal RTC

  • Blue-Right-Arrow MODBUS/TCP multi-drop communication for PLC, SCADA, etc

  • Blue-Right-Arrow FDA 21 CFR Part 11Compliance EMS software

  • Blue-Right-Arrow Advance digital RH+T sensor technology

  • Blue-Right-Arrow Door Status & AHU Status Optional

  • Blue-Right-Arrow Micro-controller based

  • Blue-Right-Arrow RH, Temperature & DP measurement

  • Blue-Right-Arrow Seven Segment 4 digit display

  • Blue-Right-Arrow Software Programmable channel ranges, unit & input types

  • Blue-Right-Arrow User programmable for 1,2 or 3 channel measurement

  • Blue-Right-Arrow Real time clock with battery back-up with internal RTC

  • Blue-Right-Arrow MODBUS/TCP multi-drop communication for PLC, SCADA, etc

  • Blue-Right-Arrow FDA 21 CFR Part 11Compliance EMS software

  • Blue-Right-Arrow Advance digital RH+T sensor technology

  • Blue-Right-Arrow Door Status & AHU Status Optional

  • Blue-Right-Arrow Automatic generation of reports in PDF format. No software required

  • Blue-Right-Arrow Low cost - one time use, no need to return to the sender of the load

  • Blue-Right-Arrow Built-in USB interface

  • Blue-Right-Arrow Compact (credit card format), waterproof (IP67), non-toxic - can be used to contact food

  • Blue-Right-Arrow Alarm indicator - flashing LED

  • Blue-Right-Arrow Individual requirements pre-programmed (duration, alarm limits, alarm delay, alarm mode, start delay)

  • Blue-Right-Arrow Certification according to CE, EN12830, RTCA-D0160G

  • Blue-Right-Arrow Automatic generation of reports in PDF format. No software required

  • Blue-Right-Arrow Low cost - one time use, no need to return to the sender of the load

  • Blue-Right-Arrow Built-in USB interface

  • Blue-Right-Arrow Compact (credit card format), waterproof (IP67), non-toxic - can be used to contact food

  • Blue-Right-Arrow Alarm indicator - flashing LED

  • Blue-Right-Arrow Individual requirements pre-programmed (duration, alarm limits, alarm delay, alarm mode, start delay)

  • Blue-Right-Arrow Certification according to CE, EN12830, RTCA-D0160G

Technical Information

Parameter Description
Display Type Seven Seven Segment 4 Digit Display. Row1:Menu/Parameter Row2: Process Value
LED Indication Alarm:High/ Low, Memory Full Alarm & Digital InputUnit's Parameter (Pascal/ mm WC,°C/ °F,% RH,)
Transaction Capacity 10,000 (Optional as per model)
Number of Channels Three
Channel Types 1.Differential Pressure 2.Temperature 3. RelativeHumidity
Sensor Types
  • 1. Differential Pressure (InternalSensor)
  • 2. Digital Temperature &Humidity (Internal Sensor)
  • 3. Relative Humidity: (0 to 100% RH)
  • 4. Digital Temperature: 0-100°C.
  • 5. Digital Humidity: 0-100%RH
Input Range
  • 1. Diff.Pressure:(0to100mm WC)(Inbuilt)
  • 2. Temperature:PT100:(-090°Cto390°C)
  • 3. RelativeHumidity:(0to100%RH)
  • 4. Digital Temperature: 0-100°c
  • 5. Digital Humidity: 0-100%RH
Channel Resolution
  • 1. Diff. Pressure : 0.1 mmWC
  • 2. PT100 : 0.1°C
  • 3. Relative Humidity : 2% RH
  • 4. Digital Temperature : ± 0.3°C
  • 5. Digital Humidity : ± 2.0% RH
Accuracy
  • 1. DP : 1.5% Full Scale
  • 2. PT100 : 0.5°C
  • 3. RH: 2% (Depending on Sensor)
  • 4. Temperature: ±0.3°C
  • 5. Humidity :± 2.0% RH
Communication Port 2 Nos Rs485 (1st Rs485 for PC Comm./MODBUS & 2nd for External Display)
Alarm Output External potential free relay output for external Hooter/ Buzzer
Event Door Open/Close status (optional)
top arrow