smart-arrow

enviroSCAN - 4/8/16/32

Multichannel-data-loggers-for-pharma-warehouses
smart-arrow

enviroSCAN

Real Time Temperature&Humidity Monitoring Solution for Multi-location Pharma Warehouses in the Cold Chain

enviroSCAN, the Multi Channel Scanners & Data Loggers along with Web based Enviro multi-location Warehouses Monitoring Software, together monitor the temperature and RH under which your vital medicines and vaccines are stored in the network of your warehouses in the Cool Chain and thus assist you in your Good Distribution Practices (GDP)
  • If either the temperature or the RH starts deviating from the range or limits set by you in any warehouse or chamber, you will get the news by way of a SMS Alert and an email for you to take action. • Enviro multi-location warehouses monitoring software & mobile app helps monitoring on Real Time basis from anytime anywhere for authorized user only

  • Equipment name tagging feature enables you to identify the exact area/location in any of the warehouses in your network

  • Ultra Sub Zero to low Temperature and 0% to 100% RH monitoring assuring high data integrity

  • Provides various rich MIS reports and graphs, in US FDA 21 CFR compliant format, such as the Mean Kinetic Temperature (MKT) and Time Temperature Integration (TTI) in PDF

  • Being TCP/IP based provides scalability within site & across multi-site locations Solutions from Enviro Technologies for Accurate, Tamper Proof and therefore Authentic an Reliable monitoring of environmental parameters - to ensure GMP, GDP & Data Integrity

Technical Information

Parameter Description
No of Channels 8/16/24 channels universal data logger (depending on user requirement you can connect any type of sensor)
Sensor Input
  • 1. Temperature: RTD PT-100 (2 or 3wire)
  • 2. Linear Inputs: 4mA -20mA,0mA - 20mA, 0-1 V, 0-5V
  • 3. Humidity RH: 0-1V,0-3.3V
Sensor Range
  • 1. Temperature: RTD PT-100: -200 C to +850 C
  • 2. Humidity : 0 to 100% Rh
Temperature Resolution
  • 1. 0.1°C to 1°C subject to input
  • 2. RTD: 0.1° C
Reading Interval 1 min to 255 mins (User defined)
Sensor Accuracy/ Tolerance
  • RID:±0-5 + subject to input
  • For all other: subject to input
Display
  • Large 7" TFT non touch display (optional)
  • 128 x 64 Graphical LCD for user setting
Data Logging Real time data logging with date&time as per user programmable logging interval
Memory Capacity 15000 transactions
Adapter Supply Voltage 110/230 V AC - 50/60 Hz&12V DC/ 1A adapter
PC Communication TCP/IP, RS485 MODBUS with BMS Integration
Relay Output 8 Relays output with external card(Optional)
Audible Alarm On Board Buzzer(Optional-External Hooter)
Size 200 x 120 x 50 mm with standard Din rail mounting in Compact MS powder coated cabinet